Çözümler
Horse Construction, teknik destekler, dokümantasyon destekleri, ürün destekleri, yazılım destekleri, proje destekleri ile tam bir yapısal güçlendirme malzemesi yelpazesi sunar.
The difference between the masonry structure and the concrete structure of externally bonding carbon fiber reinfroced polymer(CFRP) sheet:Substrate difference,Material surface difference,Construction methods difference
The difference between the masonry structure and the concrete structure of externally bonding carbon fiber reinfroced polymer(CFRP) sheet:
1.Substrate difference
When the masonry structure is bonded with carbon fiber cloth, the base material is made up of two materials, brick and mortar, because masonry building is built by single brick and mortar, and the saturation of mortar can not be effectively controlled, and its integrity and quality are poor.
When the concrete structure is bonded with carbon fiber cloth, the base material is concrete, and the concrete is the engineering composite material cemented by cementitious material to aggregate. The concrete can be regarded as homogeneous and continuous material, and has good integrity.
2.Material surface difference
Masonry structure is composed of a large number of bricks and mortar piled up, the structure of the existence of a large number of mortar, mortar mortar between the full degree of inconsistency, and different block strength are not the same, no unified evaluation of its surface strength, can only be used to determine the surface strength of brick and mortar. In general, the surface strength of the masonry structure is not as good as the surface strength of the concrete structure.
High strength concrete structure surface, according to the GB50367-2013 "reinforced concrete structure design specification" set when the concrete CFRP reinforcement when the concrete surface strength of not less than C15, and the concrete surface tensile bond strength shall not be less than 1.5MPa.
3.Construction methods difference
When the masonry structure reinforced with carbon fiber, the surface defects of the masonry structure needs to be repaired, and then on the wall and column surface must first do a layer of cement mortar screeding layer, the layer thickness should not be less than 15mm and flat, the strength of cement mortar shall not be less than M10, the smooth curved layer after curing, in accordance with the method paste carbon fiber to concrete structure construction.
When the carbon fiber cloth and concrete structure, need to be polished with new reinforced concrete, loose concrete removed, clean the surface of concrete member and yang angle round process, there will be defects repaired, and then paste the carbon fiber cloth construction.
Burada ihtiyacınız olan her şeyi bulabilirsiniz. Bu ürünleri denemeye güvenin, sonra büyük bir fark göreceksiniz.
Horse Construction'ın karbon fiberi, binalar, köprüler, otoyollar, demiryolları, tüneller, iskeleler ve sivil havaalanlarındaki beton, duvarcılık, çelik ve ahşap alt tabakaların yapısal güçlendirilmesi, onarımı ve yenilenmesi içindir.
HM-180 karbon fiber astarı düşük viskoziteli, güçlü penetrasyon yeteneğine sahip yapıştırıcıdır, takviyeli elemanların yüzeyinin alt tabakasının bulaşması için kullanılır, rolü kesilerek çıkarıldıktan sonra kırık betona takviyeyi bağlamaktır; elemanların y
Düşük viskoziteli, iyi emdirme, belirli tiksotropik özelliğe sahip, takviyeli bileşen yüzeyi ve elyaf ürünlerinin emdirilmesi ve yapıştırılması için kullanılır. Horse karbon fiber yapıştırıcısının görevi, elyaf ürünlerine tamamen batırılması ve elyaf ürünl